      Background

      Traditional monoblock pegged glenoid components are implanted with cement, increasing operative time and potentially violating more bone than those inserted without cement. We study the early radiographic loosening and reoperation rate following uncemented fixation of a hybrid cage monoblock polyethylene glenoid component.

      Methods

      Between 2013 and 2015, a total of 51 shoulders underwent anatomic shoulder arthroplasty (TSA) using a hybrid ingrowth cage polyethylene glenoid component by a single surgeon, with a minimum follow-up of 2 years. In all cases, the glenoid component was placed without cement. Mean follow-up was 33 months (range, 24-57). The primary outcome was Lazarus scale–assessed radiographic loosening. Secondary outcomes included reoperation, range of motion (ROM), and patient-reported outcome measures (PROMs).

      Results

      Twelve glenoid components (24%) had radiolucent lines. Glenoid lines were rated grade 1, grade 2, and grade 5 (6, 4, and 2 shoulders, respectively). Six shoulders (12%) had humeral lucent lines. Two shoulders (4%) underwent reoperation, only 1 of these occurring due to isolated failure of the glenoid component. As a group, mean ROM and PROMs improved significantly compared with preoperative values and exceeded the minimal clinically important difference.

      Conclusion

      Glenoid loosening remains a major concern at mid- to long-term follow-up of TSA. Placement of this hybrid cage monoblock polyethylene glenoid component in a completely uncemented fashion does not lead to early clinical loosening, after which bony ingrowth into the central cage can be expected. Uncemented fixation of this hybrid cage component appears to be a safe treatment option for patients undergoing primary TSA.

      Level of evidence

      Keywords

      To read this article in full you will need to make a payment

      References

        • Bercik M.J.
        • Kruse K.
        • Yalizis M.
        • Gauci M.-O.
        • Chaoui J.
        • Walch G.
        A modification to the Walch classification of the glenoid in primary glenohumeral osteoarthritis using three-dimensional imaging.
        J Shoulder Elbow Surg. 2016; 25: 1601-1606https://doi.org/10.1016/j.jse.2016.03.010
        • Budge M.D.
        • Nolan E.M.
        • Heisey M.H.
        • Baker K.
        • Wiater J.M.
        Results of total shoulder arthroplasty with a monoblock porous tantalum glenoid component: a prospective minimum 2-year follow-up study.
        J Shoulder Elbow Surg. 2013; 22: 535-541https://doi.org/10.1016/j.jse.2012.06.001
        • Calcei J.G.
        • Berhouet J.
        • Elpers M.
        • Catanzano A.
        • Wright T.M.
        • Craig E.V.
        • et al.
        Retrieval analysis of porous titanium glenoid posts: an evaluation of osteointegration.
        Orthopedics. 2017; 40: e703-e707https://doi.org/10.3928/01477447-20170522-04
        • Collins D.
        • Tencer A.
        • Sidles J.
        • Matsen 3rd, F.
        Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone.
        J Bone Joint Surg Am. 1992; 74: 501-507
        • De Wilde L.
        • Dayerizadeh N.
        • De Neve F.
        • Basamania C.
        • Van Tongel A.
        Fully uncemented glenoid component in total shoulder arthroplasty.
        J Shoulder Elbow Surg. 2013; 22: e1-e7https://doi.org/10.1016/j.jse.2013.01.036
        • Endrizzi D.P.
        • Mackenzie J.A.
        • Henry P.D.G.
        Early debris formation with a porous tantalum glenoid component: radiographic analysis with 2-year minimum follow-up.
        J Bone Joint Surg Am. 2016; 98: 1023-1029https://doi.org/10.2106/JBJS.15.00410
        • Flurin P.-H.
        • Marczuk Y.
        • Janout M.
        • Wright T.W.
        • Zuckerman J.
        • Roche C.P.
        Comparison of outcomes using anatomic and reverse total shoulder arthroplasty.
        Bull Hosp Jt Dis (2013). 2013; 71: 101-107
        • Fox T.J.
        • Foruria A.M.
        • Klika B.J.
        • Sperling J.W.
        • Schleck C.D.
        • Cofield R.H.
        Radiographic survival in total shoulder arthroplasty.
        J Shoulder Elbow Surg. 2013; 22: 1221-1227https://doi.org/10.1016/j.jse.2012.12.034
        • Friedman R.J.
        • Cheung E.
        • Grey S.G.
        • Flurin P.H.
        • Wright T.W.
        • Zuckerman J.D.
        • et al.
        Clinical and radiographic comparison of a hybrid cage glenoid to a cemented polyethylene glenoid in anatomic total shoulder arthroplasty.
        J Shoulder Elbow Surg. 2019; ([Epub ahead of print])https://doi.org/10.1016/j.jse.2019.04.049
        • Grey S.G.
        • Wright T.W.
        • Flurin P.H.
        • Zuckerman J.D.
        • Friedman R.
        • Roche C.P.
        Preliminary results of a novel hybrid cage glenoid compared to an all-polyethylene glenoid in total shoulder arthroplasty.
        Bull Hosp Jt Dis (2013). 2015; 73: S86-S91
        • Gulotta L.V.
        • Chambers K.L.
        • Warren R.F.
        • Dines D.M.
        • Craig E.V.
        No differences in early results of a hybrid glenoid compared with a pegged implant.
        Clin Orthop Relat Res. 2015; 473: 3918-3924https://doi.org/10.1007/s11999-015-4558-5
        • Kilian C.M.
        • Morris B.J.
        • Sochacki K.R.
        • Gombera M.M.
        • Haigler R.E.
        • O’Connor D.P.
        • et al.
        Radiographic comparison of finned, cementless central pegged glenoid component and conventional cemented pegged glenoid component in total shoulder arthroplasty: a prospective randomized study.
        J Shoulder Elbow Surg. 2018; 27: S10-S16https://doi.org/10.1016/j.jse.2017.09.014
        • Kilian C.M.
        • Press C.M.
        • Smith K.M.
        • O'Connor D.P.
        • Morris B.J.
        • Elkousy H.A.
        • et al.
        Radiographic and clinical comparison of pegged and keeled glenoid components using modern cementing techniques: midterm results of a prospective randomized study.
        J Shoulder Elbow Surg. 2017; 26: 2078-2085https://doi.org/10.1016/j.jse.2017.07.016
        • Lazarus M.D.
        • Jensen K.L.
        • Southworth C.
        • Matsen 3rd, F.
        The radiographic evaluation of keeled and pegged glenoid component insertion.
        J Bone Joint Surg Am. 2002; 84: 1174-1182https://doi.org/10.2106/00004623-200207000-00013
        • McLendon P.B.
        • Schoch B.S.
        • Sperling J.W.
        • Sánchez-Sotelo J.
        • Schleck C.D.
        • Cofield R.H.
        Survival of the pegged glenoid component in shoulder arthroplasty: part II.
        J Shoulder Elbow Surg. 2017; 26: 1469-1476https://doi.org/10.1016/j.jse.2016.12.068
        • Merolla G.
        • Ciaramella G.
        • Fabbri E.
        • Walch G.
        • Paladini P.
        • Porcellini G.
        Total shoulder replacement using a bone ingrowth central peg polyethylene glenoid component: a prospective clinical and computed tomography study with short- to mid-term follow-up.
        Int Orthop. 2016; 40: 2355-2363https://doi.org/10.1007/s00264-016-3255-7
        • Mileti J.
        • Sperling J.W.
        • Cofield R.H.
        • Harrington J.R.
        • Hoskin T.L.
        Monoblock and modular total shoulder arthroplasty for osteoarthritis.
        J Bone Joint Surg Br. 2005; 87: 496-500https://doi.org/10.1302/0301-620X.87B4.15558
        • Nelson C.G.
        • Brolin T.J.
        • Ford M.C.
        • Smith R.A.
        • Azar F.M.
        • Throckmorton T.W.
        Five-year minimum clinical and radiographic outcomes of total shoulder arthroplasty using a hybrid glenoid component with a central porous titanium post.
        J Shoulder Elbow Surg. 2018; 27: 1462-1467https://doi.org/10.1016/j.jse.2018.01.012
        • Parks D.L.
        • Casagrande D.J.
        • Schrumpf M.A.
        • Harmsen S.M.
        • Norris T.R.
        • Kelly J.D.
        Radiographic and clinical outcomes of total shoulder arthroplasty with an all-polyethylene pegged bone ingrowth glenoid component: prospective short- to medium-term follow-up.
        J Shoulder Elbow Surg. 2016; 25: 246-255https://doi.org/10.1016/j.jse.2015.07.008
        • Sanchez-Sotelo J.
        • O'Driscoll S.W.
        • Torchia M.E.
        • Cofield R.H.
        • Rowland C.M.
        Radiographic assessment of cemented humeral components in shoulder arthroplasty.
        J Shoulder Elbow Surg. 2001; 10: 526-531
        • Sanchez-Sotelo J.
        • Wright T.W.
        • O'Driscoll S.W.
        • Cofield R.H.
        • Rowland C.M.
        Radiographic assessment of uncemented humeral components in total shoulder arthroplasty.
        J Arthroplasty. 2001; 16: 180-187
        • Sarah J.
        • Sanjay G.
        • Sanjay S.
        • Carolyn A.
        • Emery R.
        • Andrew A.
        • et al.
        Failure mechanism of the all-polyethylene glenoid implant.
        J Biomech. 2010; 43: 714-719https://doi.org/10.1016/j.jbiomech.2009.10.019
        • Schoch B.
        • Werthel J.D.
        • Schleck C.D.
        • Harmsen W.S.
        • Sperling J.
        • Sánchez-Sotelo J.
        • et al.
        Optimizing follow-up after anatomic total shoulder arthroplasty.
        J Shoulder Elbow Surg. 2017; 26: 997-1002https://doi.org/10.1016/j.jse.2016.10.024
        • Walch G.
        • Boulahia A.
        • Boileau P.
        • Kempf J.F.
        Primary glenohumeral osteoarthritis: clinical and radiographic classification. The Aequalis Group.
        Acta Orthop Belg. 1998; 64: 46-52
        • Wiater B.P.
        • Moravek J.E.
        • Kurdziel M.D.
        • Baker K.C.
        • Wiater J.M.
        Biomechanical evaluation of all-polyethylene pegged bony ingrowth glenoid fixation techniques on implant micromotion.
        Am J Orthop (Belle Mead NJ). 2016; 45: E211-E216
        • Wirth M.A.
        • Loredo R.
        • Garcia G.
        • Rockwood C.A.
        • Southworth C.
        • Iannotti J.P.
        Total shoulder arthroplasty with an all-polyethylene pegged bone-ingrowth glenoid component: a clinical and radiographic outcome study.
        J Bone Joint Surg Am. 2012; 94: 260-267https://doi.org/10.2106/JBJS.J.01400
        • Yian E.H.
        • Werner C.M.L.
        • Nyffeler R.W.
        • Pfirrmann C.W.
        • Ramappa A.
        • Sukthankar A.
        • et al.
        Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement.
        J Bone Joint Surg Am. 2005; 87: 1928-1936https://doi.org/10.2106/JBJS.D.02675