Advertisement
Journal of Shoulder and Elbow Surgery

Repair results of 2-tendon rotator cuff tears utilizing the transosseous equivalent technique

Published:August 05, 2010DOI:https://doi.org/10.1016/j.jse.2010.03.018

      Background

      The purpose of this study was to examine the healing rate of 2-tendon rotator cuff tears repaired by the use of a transosseous-equivalent (TOE) suture bridge technique.

      Materials and methods

      Forty-three patients with combined supraspinatus and infraspinatus tendon tears underwent arthroscopic repair using TOE technique. Forty of these patients were then evaluated by MRI and clinical exam at a minimum of 1-year follow-up to determine the rate of healing of the repair and clinical outcomes associated with healing.

      Results

      Eighty-three percent of the repairs demonstrated intact rotator cuff repairs at a mean of 16 months post-op. Larger tears (3.5 vs 2.8 cm) were associated with failure (P = .01), as was more advanced fatty infiltration (Goutallier 1.3 vs 0.3, P = .01). Age was not different between intact and nonintact tendons. Strength was the only clinical finding that differed between intact and nonintact tendons.

      Conclusion

      Two-tendon tears of the rotator cuff can heal at a high rate with the use of TOE suture bridge repair technique. Furthermore, tear size and Goutallier grading were negatively correlated with postoperative healing. The incremental improvement in the rate of observed rotator cuff healing still does not translate to statistical differences in the objective shoulder scoring systems.

      Level of evidence

      Keywords

      To read this article in full you will need to make a payment

      References

        • Anderson K.
        • Boothby M.
        • Aschenbrener D.
        • van Holsbeeck M.
        Outcome and structural integrity after arthroscopic rotator cuff repair using 2 rows of fixation: minimum 2-year follow-up.
        Am J Sports Med. 2006; 34: 1899-1905https://doi.org/10.1177/0363546506290187
        • Bishop J.
        • Klepps S.
        • Lo I.K.
        • Bird J.
        • Gladstone J.N.
        • Flatow E.L.
        Cuff integrity after arthroscopic versus open rotator cuff repair: a prospective study.
        J Shoulder Elbow Surg. 2006; 15: 290-299https://doi.org/10.1016/j.jse.2005.09.017
        • Bisson L.J.
        • Manohar L.M.
        A biomechanical comparison of transosseous-suture anchor and suture bridge rotator cuff repairs in cadavers.
        Am J Sports Med. 2009; 37: 1991-1995https://doi.org/10.1177/0363546509336260
        • Boileau P.
        • Brassart N.
        • Watkinson D.J.
        • Carles M.
        • Hatzidakis A.M.
        • Krishnan S.G.
        Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal?.
        J Bone Joint Surg Am. 2005; 87: 1229-1240https://doi.org/10.2106/JBJS.D.02035
        • Burks R.T.
        • Crim J.
        • Brown N.
        • Fink B.
        • Greis P.E.
        A prospective randomized clinical trial comparing arthroscopic single- and double-row rotator cuff repair: magnetic resonance imaging and early clinical evaluation.
        Am J Sports Med. 2009; 37: 674-682https://doi.org/10.1177/0363546508328115
        • Charousset C.
        • Grimberg J.
        • Duranthon L.D.
        • Bellaiche L.
        • Petrover D.
        Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair? A prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment.
        Am J Sports Med. 2007; 35: 1247-1253https://doi.org/10.1177/0363546507301661
        • Curtis A.S.
        • Burbank K.M.
        • Tierney J.J.
        • Scheller A.D.
        • Curran A.R.
        The insertional footprint of the rotator cuff: an anatomic study.
        Arthroscopy. 2006; 22 (e1. doi:10.1177/0363546507301661): 609
        • DeOrio J.K.
        • Cofield R.H.
        Results of a second attempt at surgical repair of a failed initial rotator-cuff repair.
        J Bone Joint Surg Am. 1984; 66: 563-567
        • Franceschi F.
        • Ruzzini L.
        • Longo U.G.
        • Martina F.M.
        • Zobel B.B.
        • Maffulli N.
        • et al.
        Equivalent clinical results of arthroscopic single-row and double-row suture anchor repair for rotator cuff tears: a randomized controlled trial.
        Am J Sports Med. 2007; 35: 1254-1260https://doi.org/10.1177/0363546507302218
        • Frank J.B.
        • ElAttrache N.S.
        • Dines J.S.
        • Blackburn A.
        • Crues J.
        • Tibone J.E.
        Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair.
        Am J Sports Med. 2008; 36: 1496-1503https://doi.org/10.1177/0363546507313574
        • Fuchs B.
        • Weishaupt D.
        • Zanetti M.
        • Hodler J.
        • Gerber C.
        Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging.
        J Shoulder Elbow Surg. 1999; 8: 599-605
        • Galatz L.M.
        • Ball C.M.
        • Teefey S.A.
        • Middleton W.D.
        • Yamaguchi K.
        The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears.
        J Bone Joint Surg Am. 2004; 86-A: 219-224
        • Goutallier D.
        • Postel J.M.
        • Bernageau J.
        • Lavau L.
        • Voisin M.C.
        Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan.
        Clin Orthop Relat Res. 1994; 304: 78-83
        • Goutallier D.
        • Postel J.M.
        • Gleyze P.
        • Leguilloux P.
        • Van Driessche S.
        Influence of cuff muscle fatty degeneration on anatomic and functional outcomes after simple suture of full-thickness tears.
        J Shoulder Elbow Surg. 2003; 12: 550-554https://doi.org/10.1016/S1058274603002118
        • Kuhn J.E.
        • Dunn W.R.
        • Ma B.
        • Wright R.W.
        • Jones G.
        • Spencer E.E.
        • et al.
        Interobserver agreement in the classification of rotator cuff tears.
        Am J Sports Med. 2007; 35: 437-441https://doi.org/10.1177/0363546506298108
        • Mochizuki T.
        • Sugaya H.
        • Uomizu M.
        • Maeda K.
        • Matsuki K.
        • Sekiya I.
        • et al.
        Humeral insertion of the supraspinatus and infraspinatus. New anatomical findings regarding the footprint of the rotator cuff.
        J Bone Joint Surg Am. 2008; 90: 962-969https://doi.org/10.2106/JBJS.H.01426
        • Nho S.J.
        • Adler R.S.
        • Tomlinson D.P.
        • Allen A.A.
        • Cordasco F.A.
        • Warren R.F.
        • et al.
        Arthroscopic rotator cuff repair: prospective evaluation with sequential ultrasonography.
        Am J Sports Med. 2009; 37: 1938-1945https://doi.org/10.1177/0363546509335764
        • Nho S.J.
        • Shindle M.K.
        • Adler R.S.
        • Warren R.F.
        • Altchek D.W.
        • MacGillivray J.D.
        Prospective analysis of arthroscopic rotator cuff repair: subgroup analysis.
        J Shoulder Elbow Surg. 2009; 18: 697-704https://doi.org/10.1016/j.jse.2008.11.018
        • Park J.Y.
        • Lhee S.H.
        • Choi J.H.
        • Park H.K.
        • Yu J.W.
        • Seo J.B.
        Comparison of the clinical outcomes of single- and double-row repairs in rotator cuff tears.
        Am J Sports Med. 2008; 36: 1310-1316https://doi.org/10.1177/0363546508315039
        • Park M.C.
        • Cadet E.R.
        • Levine W.N.
        • Bigliani L.U.
        • Ahmad C.S.
        Tendon-to-bone pressure distributions at a repaired rotator cuff footprint using transosseous suture and suture anchor fixation techniques.
        Am J Sports Med. 2005; 33: 1154-1159https://doi.org/10.1177/0363546504273053
        • Park M.C.
        • Elattrache N.S.
        • Ahmad C.S.
        • Tibone J.E.
        “Transosseous-equivalent” rotator cuff repair technique.
        Arthroscopy. 2006; 22 (e1-5. doi:10.1016/j.arthro.2006.07.017): 1360
        • Park M.C.
        • ElAttrache N.S.
        • Tibone J.E.
        • Ahmad C.S.
        • Jun B.J.
        • Lee T.Q.
        Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique.
        J Shoulder Elbow Surg. 2007; 16: 461-468https://doi.org/10.1016/j.jse.2006.09.010
        • Sugaya H.
        • Maeda K.
        • Matsuki K.
        • Moriishi J.
        Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study.
        J Bone Joint Surg Am. 2007; 89: 953-960https://doi.org/10.2106/JBJS.F.00512
        • Sugaya H.
        • Maeda K.
        • Matsuki K.
        • Moriishi J.
        Functional and structural outcome after arthroscopic full-thickness rotator cuff repair: single-row versus dual-row fixation.
        Arthroscopy. 2005; 21: 1307-1316https://doi.org/10.1016/j.arthro.2005.08.011
        • Williams M.D.
        • Ladermann A.
        • Melis B.
        • Barthelemy R.
        • Walch G.
        Fatty infiltration of the supraspinatus: a reliability study.
        J Shoulder Elbow Surg. 2009; 18: 581-587https://doi.org/10.1016/j.jse.2008.12.014