Journal of Shoulder and Elbow Surgery
Volume 19, Issue 2, Supplement , Pages 83-90, March 2010

Arthroscopic rotator cuff repair: Scientific rationale, surgical technique, and early clinical and functional results of a knotless self-reinforcing double-row rotator cuff repair system

  • Suketu Vaishnav, MD
  • ,
  • Peter J. Millett, MD, MSc

      Affiliations

    • Corresponding Author InformationReprint requests: Peter J. Millett, MD, MSc, Steadman Philippon Research Institute. Attn: Clinical Research, 181 West Meadow Drive, Suite 1000, Vail, CO 81657.

Steadman Philippon Research Institute, Vail, CO

Background

Rotator cuff repair has shown to improve shoulder function and reduce pain experienced by patients. Successful repairs should have high fixation strength, allow minimal gap formation, maintain stability, and restore normal anatomy and function of the supraspinatus footprint. The purpose of this study is to describe our preferred method for rotator cuff repair using a knotless self-reinforcing double-row system, and to cite biomenchanical data rationalizing its use.

Methods and material

Seventeen of 22 patients were identified as undergoing primary rotator cuff repair with minimum follow-up of 1 year (mean, 535 days; range, 370-939). The average age was 63 (range, 43-79). Data collected included average pain today, average worst pain, Single Assessment Numeric Evaluation (SANE), and patient satisfaction.

Results

For all patients, average pain today and average worst pain decreased and functional scores (SANE) increased. Patient satisfaction was 9.8 out of 10 (range, 7-9). The patients also began rehabilitation earlier and returned to full activities at 4 months.

Conclusion

These results indicate that the knotless self-reinforcing double-row repair system is a viable option in treating rotator cuff tears. This system provides improved contact area and restores the native footprint of the tendon leading to better outcomes.

Level of Evidence: Level IV, Case Series, Treatment Study

Keywords: Double-row rotator cuff repair, minimize tendon gap formation, improve contact area for rotator cuff repair

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(09)00566-7

doi:10.1016/j.jse.2009.12.012

Journal of Shoulder and Elbow Surgery
Volume 19, Issue 2, Supplement , Pages 83-90, March 2010