Journal of Shoulder and Elbow Surgery
Volume 19, Issue 5 , Pages 726-733 , July 2010

Pegged versus keeled glenoid components in total shoulder arthroplasty

References 

  1. Braman JP, Falicov A, Boorman R, Matsen FA. Alterations in surface geometry in retrieved polyethylene glenoid component. J Orthop Res. 2006;24:1249–1260
  2. Buckingham BP, Parson IM, Campbell B, Titelman RM, Smith KL, Matsen FA. Patient functional self-assessment in late glenoid component failure at three to eleven years after total shoulder arthroplasty. J Shoulder Elbow Surg. 2005;14:368–374
  3. Edwards TB, Sabonghy EP, Elkousy H, Warnock KM, Hammerman SM, O'Connor DP, et al. Glenoid component insertion in total shoulder arthroplasty: comparison of three techniques for drying the glenoid before cementation. J Shoulder Elbow Surg. 2007;16(Suppl):S107–S110
  4. Franklin JL, Barrett WP, Jackins SE, Matsen FA. Glenoid loosening in total shoulder arthroplasty: association with rotator cuff deficiency. J Arthroplasty. 1988;3:39–46
  5. Franta AK, Lenters TR, Mounce D, Neradilek B, Matsen FA. The complex characteristics of 282 unsatisfactory shoulder arthroplasties. J Shoulder Elbow Surg. 2007;16:555–562
  6. Gartsman GM, Elkousy HA, Warnock KM, Edwards TB, O'Connor DP. Radiographic comparison of pegged and keeled glenoid components. J Shoulder Elbow Surg. 2005;14:252–257
  7. Gupta S, van der Helm FC, van Keulen F. Stress analysis of cemented glenoid prostheses in total shoulder arthroplasty. J Biomech. 2004;37:1777–1786
  8. Hopkins AR, Hansen UN, Amis AA, Emery R. The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty. J Shoulder Elbow Surg. 2004;13:668–675
  9. Lacroix D, Murphy LA, Prendergast PJ. Three-dimensional finite element analysis of glenoid replacement prostheses: a comparison of keeled and pegged anchorage systems. J Biomech Eng. 2000;122:430–436
  10. Lacroix D, Prendergast PJ. Stress analysis of glenoid component designs for total shoulder arthroplasty. Proc Inst Mech Eng H. 1997;211:467–474
  11. Lazarus MD, Jensen KL, Southworth C, Matsen FA. The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am. 2002;84:1174–1182
  12. Mansat P, Briot J, Mansat M, Swider P. Evaluation of the glenoid implant survival using a biomechanical finite element analysis: influence of the implant design, bone properties, and loading location. J Shoulder Elbow Surg. 2007;16(Suppl):S79–S83
  13. Mileti J, Boardman ND, Sperling JW, Cofield RH, Torchia ME, O'Driscoll SW, et al. Radiographic analysis of polyethylene glenoid components using modern cementing techniques. J Shoulder Elbow Surg. 2004;13:492–498
  14. Nagels J, Valstar ER, Stokdijk M, Rozing PM. Patterns of loosening of the glenoid component. J Bone Joint Surg Br. 2002;84:83–87
  15. Neer CS, Watson KC, Stanton FJ. Recent experience in total shoulder replacement. J Bone Joint Surg Am. 1982;64:319–337
  16. Nuttall D, Haines JF, Trail . A study of the microenvironment of pegged and keeled glenoid components compared using radiostereometric analysis. J Shoulder Elbow Surg. 2007;16(Suppl):S65–S70
  17. Nyffeler RW, Anglin C, Sheikh R, Gerber C. Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs. J Bone Joint Surg Br. 2003;85:748–752
  18. Nyffeler RW, Meyer D, Sheikh R, Koller BJ, Gerber C. The effect of cementing technique on structural fixation of pegged glenoid components in total shoulder arthroplasty. J Shoulder Elbow Surg. 2006;15:106–111
  19. O'Driscoll SW, Wright TW, Cofield RH, Ilstrup D, Mansat P. Problemes glenoidiens: evaluation radiographique du composant glenoidien dans les prostheses totals d'epaule. In:  Mansat M editors. Protheses d'epaule. Cahiers d'enseignement de la SOFCOT, No. 68. Paris: Expansion Scientifique Publications; 1999;p. 337–344
  20. Shapiro TA, McGarry MH, Gupta R, Lee YS, Lee TQ. Biomechanical effects of glenoid retroversion in total shoulder arthroplasty. J Shoulder Elbow Surg. 2007;16(Suppl):S90–S95
  21. Sperling JW, Cofield RH, O'Driscoll SW, Torchia ME, Rowland CM. Radiographic assessment of ingrowth total shoulder arthroplasty. J Shoulder Elbow Surg. 2000;9:507–513
  22. Sperling JW, Cofield RH, Rowland CM. Minimum fifteen-year follow-up of Neer hemiarthroplasty and total shoulder arthroplasty in patients aged fifty years or younger. J Shoulder Elbow Surg. 2004;13:604–613
  23. Sperling JW, Cofield RH, Schelck CD, Harmsen WS. Total shoulder arthroplasty versus hemiarthroplasty for rheumatoid arthritis: results of 303 consecutive cases. J Shoulder Elbow Surg. 2007;16:683–690
  24. Stone KD, Grabowski JJ, Cofield RH, Morrey BF, An KN. Stress analyses of glenoid components in total shoulder arthroplasty. J Shoulder Elbow Surg. 1999;8:151–158
  25. Swieszkowski W, Bednarz P, Prendergast PJ. Contact stresses in the glenoid component in total shoulder arthroplasty. Proc Inst Mech Eng H. 2003;217:49–57
  26. Szabo I, Buscayret F, Edwards TB, Nemoz C, Boileau P, Walch G. Radiographic comparison of flat-back and convex-back glenoid components in total shoulder arthroplasty. J Shoulder Elbow Surg. 2005;14:636–642
  27. Szabo I, Buscayret F, Edwards TB, Nemoz C, O'Connor DP, Boileau P, et al. Radiographic comparison of two glenoid preparation techniques in total shoulder arthroplasty. Clin Orthop Relat Res. 2005;104–110
  28. Tammachote N, Sperling JW, Berglund LJ, Steinmann SP, Cofield RH, An KN. The effect of glenoid component size on the stability of total shoulder arthroplasty. J Shoulder Elbow Surg. 2007;16(Suppl):S102–S106
  29. Terrier A, Buchler P, Farron A. Influence of glenohumeral conformity on glenoid stresses after total shoulder arthroplasty. J Shoulder Elbow Surg. 2006;15:515–520
  30. Torchia ME, Cofield RH, Settergren CR. Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Shoulder Elbow Surg. 1997;6:495–505
  31. Walch G, Badet R, Boulahia A, Khoury A. Morphologic study of the glenoid in primary glenohumeral osteoarthritis. J Arthroplasty. 1999;14:756–760
  32. Wallace AL, Phillips RL, MacDougal GA, Walsh WR, Sonnabend DH. Resurfacing of the glenoid in total shoulder arthroplasty: a comparison, at a mean of five years, of prostheses inserted with and without cement. J Bone Joint Surg Am. 1999;81:510–518
  33. Williams GR, Abboud JA. Total shoulder arthroplasty: glenoid component design. J Shoulder Elbow Surg. 2005;14(Suppl):S122–S128
  34. Yian EH, Werner CM, Nyffeler RW, Pfirrmann CW, Ramappa A, Sukthankar A, et al. Radiographic and computed tomography analysis of cemented pegged polyethylene glenoid components in total shoulder replacement. J Bone Joint Surg Am. 2005;87:1928–1936

 Dr Cofield has a contract between Mayo Foundation and Smith & Nephew.

PII: S1058-2746(09)00467-4

doi: 10.1016/j.jse.2009.10.018

Journal of Shoulder and Elbow Surgery
Volume 19, Issue 5 , Pages 726-733 , July 2010