Journal of Shoulder and Elbow Surgery
Volume 19, Issue 1 , Pages 26-30, January 2010

The proximal ulna dorsal angulation: A radiographic study

  • Dominique M. Rouleau, MD, FRCSC
  • ,
  • Kenneth J. Faber, MD, FRCSC
  • ,
  • George S. Athwal, MD, FRCSC

      Affiliations

    • Corresponding Author InformationReprint requests: George S. Athwal, MD, FRCSC, Assistant Professor of Surgery and Consultant, Hand and Upper Limb Center, St Joseph's Health Center, University of Western Ontario, 268 Grosvenor St, London, ON, N6A 4L6 Canada.

Hand and Upper Limb Center, St Joseph's Health Care, University of Western Ontario, London, Ontario, Canada

published online 29 September 2009.

Background

Recognition of the proximal ulna dorsal angulation (PUDA) is important for anatomic reduction of proximal ulna fractures, nonunions, malunions, or osteotomies, especially when using newer straight precontoured ulnar plates. The purpose of this study was to characterize the PUDA in 50 patients with bilateral elbow radiographs.

Materials and methods

Commercial software was used to magnify 100 bilateral elbow radiographs 4 times. The PUDA was measured from the intersection of lines perpendicular to the subcutaneous border of the olecranon and the ulnar shaft. The olecranon tip-to-apex distance of the PUDA was also measured. Three orthopedic surgeons independently examined the radiographs, and intraobserver and interobserver reliability was calculated using intraclass correlation.

Results

A PUDA was present in 96% of radiographs. The average PUDA was 5.7° (range, 0°-14°). The Pearson correlation coefficient for a side-to-side comparison was 0.860 (P < .001). The average tip-to-apex distance was 47mm (range, 34-78mm). No correlation was identified with age. Intraobserver reliability was excellent for the PUDA and good for the tip-to-apex distance. Interobserver reliability was good for the PUDA and the tip-to-apex distance.

Discussion

A mean PUDA of 5.7° is present in 96% of patients at an average of 47mm distal to the olecranon tip. Measurement of the PUDA has good-to-excellent interobserver and intraobserver reliability.

Conclusion

Contralateral PUDA measurements are reliable in determining the angle in patients with comminution or distorted anatomy. Recognition of the PUDA may be helpful in anatomic plating of the ulna. Recognition of the PUDA may be helpful in anatomic plating of the ulna for fractures, nonunions or malunions.

Level of evidence

Radiographic study.

Keywords: Ulna, anatomy, Monteggia, elbow

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(09)00295-X

doi:10.1016/j.jse.2009.07.005

Journal of Shoulder and Elbow Surgery
Volume 19, Issue 1 , Pages 26-30, January 2010