Volume 18, Issue 5 , Pages 728-733, September 2009
Reliability and accuracy of templating the proximal humeral component for shoulder arthroplasty
Background
The purpose of this paper is to examine the intra-observer and inter-observer reliability of preoperative templating to help determine its usefulness for approximating proximal humeral stem and head size in shoulder arthroplasty.
Methods
Thirty-one nonconsecutive patients underwent uncemented total shoulder arthroplasty using 1 of 2 commonly used prostheses. Templating was performed by 4 independent observers (2 experienced shoulder surgeons and 2 PGY-3 residents). Two readings were performed with a minimum 2-week interval between templating sessions. Templating was performed in a blinded manner using appropriately magnified templates provided by the prosthesis manufacturer. Postoperative radiographs were analyzed in the same fashion and each observer graded qualitative stem and head size radiographically. Pre-operative templated sizes were compared to actual implant sizes obtained from dictated operative reports.
Results
There was substantial (kappa > 0.7) intraobserver reliability for stem and head size selection for both prostheses. Interobserver reliability was moderate for stem size (kappa = 0.53) and substantial (kappa = 0.66) for head size. Preoperative templating accurately predicted stem (84-95%) and head (44-66%) size within 1 size variation (stem width, head thickness, or diameter) for shoulder replacement surgery. There was no significant difference in accuracy between attendings and residents when templating for stem or head size.
Conclusion
Preoperative templating is a reliable and reasonably accurate step when planning shoulder replacement surgery. Templating for stem size is more accurate than for head size.
Level of evidence
Level IV, Case Series, Treatment Study.
Keywords: Total shoulder arthroplasty, prosthesis, templates, templating, intraobserver reliability, interobserver reliability
To access this article, please choose from the options below
Each author certifies that he has no commercial associations (eg, consultancies, stock ownership, equity interest, patent/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.
Each author certifies that his institution has waived approval for the protocol for this investigation, and that all investigations were conducted in conformity with ethical principles of research.
PII: S1058-2746(09)00028-7
doi:10.1016/j.jse.2008.11.015
© 2009 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Volume 18, Issue 5 , Pages 728-733, September 2009