Journal of Shoulder and Elbow Surgery
Volume 16, Issue 5 , Pages 544-547 , September 2007

Timing of return of subscapularis function in open capsular shift patients

  • Mark A. Slabaugh, MD

      Affiliations

    • Malcolm Grow Medical Center, Andrews AFB, MD
    • Corresponding Author InformationReprints requests: Mark Slabaugh, MD, 1050 W. Perimeter Rd, 79th MSGS/SGCXO Andrews AFB, MD 20762.
  • ,
  • Robert T. Bents, MD

      Affiliations

    • Orthopedic Center for Sports Medicine, Grants Pass, OR
  • ,
  • John M. Tokish, MD

      Affiliations

    • USAFA Hospital, US Air Force Academy, CO.

References 

  1. Ahrens PP, Walch G. Anterior instability after unconstrained shoulder arthroplasty. In:  Walch GP,  Mole D editor. 2000 shoulder prosthesis: two to ten year follow-up. Montpellier, France: Sauramps Medical; 2001;p. 359–376
  2. Chansky HA, Iannotti JP. The vascularity of the rotator cuff. Clin Sports Med. 1991;10:807–822
  3. Gerber C, Hersche O, Farron A. Isolated rupture of the subscapularis tendon. J Bone Joint Surg Am. 1996;78:1015–1023
  4. Gerber C, Krushell RJ. Isolated rupture of the tendon of the subscapularis muscle (Clinical features in 16 cases). J Bone Joint Surg Br. 1991;73:389–394
  5. Gerber C, Yian EH, Pfirrmann CA, Zumstein MA, Werner CM. Subscapularis muscle function and structure after total shoulder replacement with lesser tuberosity osteotomy and repair. J Bone Joint Surg Am. 2005;87:1739–1745
  6. Goutallier D, Postel JM, Bernageau J, Lavau L, Voisin MC. Fatty infiltration of disrupted rotator cuff muscles. Rev Rhum Engl Ed. 1995;62:415–422
  7. Greis PE, Kuhn JE, Schultheis J, Hintermeister R, Hawkins R. Validation of the lift-off test and analysis of subscapularis activity during maximal internal rotation. Am J Sports Med. 1996;24:589–593
  8. Miller SL, Hazrati Y, Klepps S, Chiang A, Flatow EL. Loss of subscapularis function after total shoulder replacement: A seldom recognized problem. J Shoulder Elbow Surg. 2003;12:29–34
  9. Resch H, Povacz P, Ritter E, Matschi W. Transfer of the pectoralis major muscle for the treatment of irreparable rupture of the subscapularis tendon. J Bone Joint Surg Am. 2000;82:372–382
  10. Stefko JM, Jobe FW, VanderWilde RS, Carden E, Pink M. Electromyographic and nerve block analysis of the subscapularis liftoff test. J Shoulder Elbow Surg. 1997;6:347–355
  11. Suenaga N, Minami A, Fujisawa H. Electromyographic analysis of internal rotational motion of the shoulder in various arm positions. J Shoulder Elbow Surg. 2003;12:501–505
  12. Tokish JM, Decker MJ, Ellis HB, Torry MR, Hawkins RJ. The belly-press test for the physical examination of the subscapularis muscle: electromyographic validation and comparison to the lift-off test. J Shoulder Elbow Surg. 2003;12:427–430

 The views expressed in this report are those of the authors and do not reflect the official policy of the Department of Defense or other departments of the United States Government.

PII: S1058-2746(07)00222-4

doi: 10.1016/j.jse.2006.11.005

Journal of Shoulder and Elbow Surgery
Volume 16, Issue 5 , Pages 544-547 , September 2007