Journal of Shoulder and Elbow Surgery
Volume 15, Issue 1 , Pages 2-6, January 2006

Augmented subscapularis muscle transposition for rotator cuff repair during shoulder arthroplasty in patients with rheumatoid arthritis

  • Nobuyuki Tanaka, MD

      Affiliations

    • Sapporo Gorinbashi Orthopedic Hospital in Gorinbashi Hospitals, Sapporo, Japan
    • Corresponding Author InformationReprint requests: Nobuyuki Tanaka, MD, Sapporo Gorinbashi Orthopedic Hospital in Gorinbashi Hospitals, 2-1, Kawazoe, Minami-ku, Sapporo, Hokkaido, 005-0802, Japan
  • ,
  • Hisashi Sakahashi, MD

      Affiliations

    • Sapporo Gorinbashi Orthopedic Hospital in Gorinbashi Hospitals, Sapporo, Japan
  • ,
  • Kazuya Hirose, MD

      Affiliations

    • Sapporo Gorinbashi Orthopedic Hospital in Gorinbashi Hospitals, Sapporo, Japan
  • ,
  • Takumi Ishima, MD

      Affiliations

    • Sapporo Gorinbashi Orthopedic Hospital in Gorinbashi Hospitals, Sapporo, Japan
  • ,
  • Seiichi Ishii, MD

      Affiliations

    • Department of Orthopedic Surgery, School of Medicine, Sapporo Medical University, Sapporo, Japan

The effectiveness of rotator cuff repair by augmented subscapularis transposition via the Leeds-Keio artificial ligament was evaluated in patients with rheumatoid arthritis undergoing total shoulder arthroplasty. The minimum follow-up period was 2 years. Final clinical scores (Hospital for Special Surgery scoring system) and the incidence of radiolucency and upward migration of shoulder components in 20 shoulders with rotator cuff repair by augmented subscapularis transposition were superior to those of 19 shoulders with cuff repair by subscapularis transposition alone and similar to those of 22 shoulders with intact rotator cuffs. In shoulders with augmented subscapularis transposition and intact cuffs, clinical scores continued to improve even after the first postoperative year. Our augmented subscapularis transposition did not increase postoperative complications. We conclude that cuff repair by augmented subscapularis transposition is an acceptable alternative for repairing a supraspinatus or supraspinatus and infraspinatus rotator cuff defect in rheumatoid arthritis patients undergoing total shoulder arthroplasty.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(05)00150-3

doi:10.1016/j.jse.2005.04.004

Journal of Shoulder and Elbow Surgery
Volume 15, Issue 1 , Pages 2-6, January 2006