Journal of Shoulder and Elbow Surgery
Volume 14, Issue 2 , Pages 201-206, March 2005

Structural and mechanical properties of the glenohumeral joint posterior capsule

  • Michael J. Bey, PhD

      Affiliations

    • Henry Ford Health System, Bone and Joint Center, Detroit, MI, USA
  • ,
  • Shawn A. Hunter, PhD

      Affiliations

    • Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
  • ,
  • Navin Kilambi, MD

      Affiliations

    • Cincinnati Sportsmedicine and Orthopaedic Center, Cincinnati, OH, USA.
  • ,
  • David L. Butler, PhD

      Affiliations

    • Department of Biomedical Engineering, University of Cincinnati, Cincinnati, OH, USA
  • ,
  • Thomas N. Lindenfeld, MD

      Affiliations

    • Cincinnati Sportsmedicine and Orthopaedic Center, Cincinnati, OH, USA.
    • Corresponding Author InformationReprint requests: Thomas N. Lindenfeld, MD, Cincinnati Sportsmedicine and Orthopaedic Center, 12115 Sheraton Ln, Cincinnati, OH 45246.

The purpose of this study was to quantify regional variations in material properties of the glenohumeral joint posterior capsule and to compare these data with the anterior band of the inferior glenohumeral ligament (AB-IGHL). Mechanical properties were determined for individual bands of the AB-IGHL, superior posterior capsule (SUP-PC), middle posterior capsule (MID-PC), and inferior posterior capsule (INF-PC). Significant differences in tissue thickness were found among the 3 posterior capsular regions and the AB-IGHL. The AB-IGHL was thicker than the MID-PC (P = .03) and INF-PC (P = .01), and the SUP-PC was thicker than the INF-PC (P = .02). Except for significant differences in failure strains, material properties were not significantly different among the 4 tissue regions. There were no significant differences between tissue bands in modulus (P = .2), maximum stress (P = .46), or strain energy density (P = .62). Specimens failed primarily near the glenoid insertion (75%), with 4 specimens failing at the humeral insertion and 2 others failing in the tissue’s mid substance.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(04)00199-5

doi:10.1016/j.jse.2004.06.016

Journal of Shoulder and Elbow Surgery
Volume 14, Issue 2 , Pages 201-206, March 2005