Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: Efficacy of prosthetic replacement and ligament repair

  • Steen Lund Jensen, MD, PhD

      Affiliations

    • Orthopaedic Research Laboratory, Aarhus University Hospital, Aarhus, Denmark
    • Corresponding Author InformationReprint requests: Steen Lund Jensen, MD, PhD, Shoulder and Elbow Clinic, Department of Orthopaedic Surgery, Bldg 9, Aarhus University Hospital, Noerrebrogade 44, DK-8000 Aarhus C, Denmark
  • ,
  • Bo Sanderhoff Olsen, MD, PhD

      Affiliations

    • Orthopaedic Research Laboratory, Aarhus University Hospital, Aarhus, Denmark
  • ,
  • Stein Tyrdal, MD, DMSc

      Affiliations

    • Day Surgery Center, Ullevål University Hospital, Oslo, Norway.
  • ,
  • Jens Ole Søjbjerg, MD

      Affiliations

    • Orthopaedic Research Laboratory, Aarhus University Hospital, Aarhus, Denmark
  • ,
  • Otto Sneppen, MD, DMSc

      Affiliations

    • Orthopaedic Research Laboratory, Aarhus University Hospital, Aarhus, Denmark

The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL repair, and (5) radial head replacement combined with LCL repair. Isolated radial head excision increased varus (mean, 4.8°) and external rotatory laxity (mean, 7.1°), as did isolated LCL division (mean, 14.1° for varus; mean, 14.7° for external rotation). After removal of both constraints, varus and external rotatory laxities were increased by 19.0° and 20.1°, respectively, compared with the intact specimens. Isolated radial head replacement reduced mean varus laxity to 14.6° and mean external rotatory laxity to 14.8°. Isolated LCL repair normalized varus laxity but resulted in a 2.9° increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints induces severe laxity, and in this case, prosthetic replacement may substitute for the constraining capacity of the native radial head. The combination of LCL repair and radial head replacement restores laxity completely, but an isolated LCL repair performs almost as well, probably by compensating for the ligamentous tension lost from radial head excision.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(04)00156-9

doi:10.1016/j.jse.2004.05.009

Journal of Shoulder and Elbow Surgery
Volume 14, Issue 1 , Pages 78-84, January 2005