Journal of Shoulder and Elbow Surgery
Volume 12, Issue 2 , Pages 117-121 , March 2003

Failure of polymerized lactic acid tacks in shoulder surgery

References 

  1. Arciero RA, Taylor DC, Snyder RJ, Uhorchak JM. Arthroscopic bioabsorbable tack stabilization of initial anterior shoulder dislocations: a preliminary report. Arthroscopy. 1995;11:410–417
  2. Athanasiou KA, Agrawal CM, Barber FA, Burkhart SS. Orthopaedic applications for PLA-PGA biodegradable polymers. Arthroscopy. 1998;14:726–737
  3. Böstman OM, Pihlajamäki HK. Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw. J Bone Joint Surg Am. 1998;80:1791–1794
  4. Burkart A, Imhoff AB, Roscher E. Foreign-body reaction to the bioabsorbable Suretac device. Arthroscopy. 2000;16:91–95
  5. Ciccone WJ, Motz C, Bentley C, Tasto JP. Bioabsorbable implants in orthopaedics: new developments and clinical applications. J Am Acad Orthop Surg. 2001;9:280–288
  6. DeBerardino TM, Arciero RA, Taylor DC, Uhorchak JM. Prospective evaluation of arthroscopic stabilization of acute, initial anterior shoulder dislocations in young athletes. Am J Sports Med. 2001;29:586–592
  7. Edwards DJ, Hoy G, Saies AD, Hayes MG. Adverse reactions to an absorbable shoulder fixation device. J Shoulder Elbow Surg. 1994;3:230–233
  8. Friederichs MG, Greis PE, Burks RT. Pitfalls associated with fixation of osteochondritis dissecans fragments using bioabsorbable screws. Arthroscopy. 2001;17:542–545
  9. Laurencin CT, Stephens S, Warren RF, Altchek DW. Arthroscopic Bankart repair using a degradable tack. A followup study using optimized indications. Clin Orthop. 1996;332:132–137
  10. Maitra RS, Brand JC, Caborn DNM. Biodegradable implants. Sports Med Arthrosc Rev. 1998;6:103–117
  11. McGuire DA, Barber FA, Elrod BF, Paulos LE. Bioabsorbable interference screws for graft fixation in anterior cruciate ligament reconstruction. Arthroscopy. 1999;15:463–473
  12. McGuire DA, Barber FA, Milchgrub S, Wolchok JC. A postmortem examination of poly-L lactic acid interference screws 4 months after implantation during anterior cruciate ligament reconstruction. Arthroscopy. 2001;17:988–992
  13. Stahelin AC, Weiler A, Rufenacht H, et al.  Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report of six cases. Arthroscopy. 1997;13:238–244
  14. Takizawa T, Akizuki S, Horiuchi H, Yasukawa Y. Foreign body gonitis caused by a broken poly-L-lactic acid screw. Arthroscopy. 1998;14:329–330
  15. Ticker JB, Lippe RJ, Barkin DE, Carroll MP. Infected suture anchors in the shoulder. Arthroscopy. 1996;12:613–615
  16. Warden WH, Friedman R, Teresi LM, Jackson DW. Magnetic resonance imaging of bioabsorbable polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction. Arthroscopy. 1999;15:474–480
  17. Warme WJ, Arciero RA, Savoie FH, Uhorchak JM, Walton M. Nonabsorbable versus absorbable suture anchors for open Bankart repair. Am J Sports Med. 1999;27:742–746

 Reprint requests: John E. Zvijac, MD, UHZ Sports Medicine Institute, 1150 Campo Sano Ave, Suite 200, Coral Gables, FL 33146. (E-mail: jzvijac@uhzsmi.com).

PII: S1058-2746(02)86822-7

doi: 10.1067/mse.2003.16

Journal of Shoulder and Elbow Surgery
Volume 12, Issue 2 , Pages 117-121 , March 2003