Journal of Shoulder and Elbow Surgery
Volume 12, Issue 2 , Pages 179-184, March 2003

The effect of infraspinatus disruption on glenohumeral torque and superior migration of the humeral head: A biomechanical study☆☆

Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic. Rochester, MN

Abstract 

Rotator cuff ruptures that extend into the infraspinatus tendon may cause dysfunction and superior migration of the humerus. The purpose of this study was to determine whether a threshold size of infraspinatus defect exists beyond which abduction torque generation decreases and superior migration of the humeral head increases. Glenohumeral abduction torque and superior humeral head translations were measured in hanging arms in neutral rotation in cadaver shoulders (n = 10). Loads were applied to the rotator cuff tendons and the middle deltoid. After sequential detachment of the infraspinatus, abduction torque progressively decreased. At three-fifths detachment, abduction torque was significantly lower than after supraspinatus release alone (52% vs 61%, P < .05). Superior translation after complete supraspinatus and infraspinatus detachment increased significantly (P < .05), but no intermediate threshold was detected. Therefore, the entire infraspinatus contributes to abduction torque generation and stabilizes the humeral head against superior subluxation. Even with a tear extending into the superior infraspinatus, the infraspinatus contributes abduction force generation across the glenohumeral joint. (J Shoulder Elbow Surg 2003;12:179-84)

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Supported by National Institutes of Health grant No. AR41171 and Mayo Foundation. N.M. was supported in part by Yamagata University, Yamagata, Japan.

☆☆ Reprint requests: Shawn W. O'Driscoll, MD, PhD, Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905. (E-mail: odriscoll.shawn@mayo.edu).

PII: S1058-2746(02)86815-X

doi:10.1067/mse.2003.9

Journal of Shoulder and Elbow Surgery
Volume 12, Issue 2 , Pages 179-184, March 2003