Volume 11, Issue 5 , Pages 413-420, September 2002
Stability of tuberosity reattachment in proximal humeral hemiarthroplasty☆
Abstract
Hemiarthroplasty can be an effective treatment for 4-part fractures of the proximal humerus; however, results are often unpredictable. Proper surgical technique is critical for success. Reconstruction of the displaced tuberosities should attempt to impart maximal interfragmentary stability. To our knowledge, a comparison of different tuberosity reconstruction methods has not been reported. We evaluated 5 techniques of tuberosity reattachment on 8 humeri. Four-part fractures were simulated by an oscillating saw in fresh-frozen cadaveric shoulders. In the control construct, the greater and lesser tuberosities were attached to the humeral shaft with nylon strap ties (2.4 × l mm) applied at 9.1 N with closure of the rotator interval. Five anatomic reconstructions were then performed:(1) the control tuberosities were attached to each other with strap ties, and (2) the control tuberosities were attached to each other with strap ties, incorporating the anterior fin of the prosthesis. To each of these 3 constructs, a circumferential cerclage (4.8 × 1.25–mm strap tie) applied at 39.2 N was placed around the tuberosities and incorporated into the medial hole of the prosthesis (techniques 3, 4, and 5). Through use of a robot articulator at a rate of 10°/s, passive external rotation from 0° to 60° was performed on the control and the 5 test constructs of each specimen. Interfragmentary displacement of the bony fragments was measured with mercury strain gauges and strain calculated. This strain was minimal and statistically less (P < .05) in those constructs in which a cerclage was used. Incorporation of the nylon strap into the fin of the prosthesis did not enhance stability. In those constructs in which a cerclage was used, maximal displacement was 0.14 ± 0.7 mm (38% ± 19% strain), as compared with 0.72 ± 0.5 mm (204% ± 133% strain) without it. Reconstruction of 4-part proximal humerus fractures with hemiarthroplasty should incorporate a circumferential medial cerclage. This will decrease interfragmentary motion and strain, maximize fracture stability, and facilitate postoperative rehabilitation. (J Shoulder Elbow Surg 2002;11:413-20)
To access this article, please choose from the options below
☆ Reprint requests: Mark A. Frankle, MD, Florida Orthopaedic Institute, 4175 Fowler Avenue, Tampe, FL 33617-2011.
PII: S1058-2746(02)00060-5
doi:10.1067/mse.2002.126098
© 2002 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Volume 11, Issue 5 , Pages 413-420, September 2002
