Journal of Shoulder and Elbow Surgery
Volume 19, Issue 2, Supplement , Pages 104-109, March 2010

Arthroscopic GraftJacket repair of rotator cuff tears

  • Ivan Wong, MD

      Affiliations

    • Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
  • ,
  • Joseph Burns, MD

      Affiliations

    • Southern California Orthopaedic Institute, Van Nuys, CA, USA
  • ,
  • Stephen Snyder, MD

      Affiliations

    • Southern California Orthopaedic Institute, Van Nuys, CA, USA
    • Corresponding Author InformationReprint requests: Dr Stephen J. Snyder, 6815 Noble Ave, Van Nuys, CA 94105-3729.

Hypothesis

Management of massive, degenerative, and irreparable rotator cuff tears is challenging. Excessive re-tear rates and poor clinical outcome after standard repair have led to alternative methods of treatment. Tendon transfers and shoulder arthroplasty have had mixed results; both are invasive procedures with high potential morbidity. We began performing rotator cuff augmentation and replacement using GraftJacket allograft acellular human dermal matrix as a biologic minimally invasive alternative in this difficult population almost 6 years ago. This article highlights our preferred arthroscopic technique and early results.

Materials and methods

From January 2004 to June 2007, 45 patients (36 men, 9 women) with massive rotator cuff tears were treated arthroscopically with the GraftJacket allograft. All patients completed a preoperative University of California, Los Angeles (UCLA) score. Follow-up was a minimum of 2 years (range, 24-68 months) and patients completed UCLA, Western Ontario Rotator Cuff (WORC), and American Shoulder and Elbow Surgeons (ASES) scores.

Results

Analysis was performed using the 3 validated outcomes measurement scores. The mean UCLA score increased from 18.4 preoperatively to 27.5 postoperatively (P < .000). The average WORC score was 75.2, and the ASES score was 84.1 at the final follow-up.

Discussion

Evidence-based data to outline an algorithm for management of irreparable rotator cuff tears is being developed. We documented significant clinical improvement with arthroscopic rotator cuff reconstruction using the GraftJacket allograft acellular human dermal matrix. The procedure is safe and associated with high patient satisfaction, without the morbidity of tendon transfer or arthroplasty. For those few cases where further surgery is required, no bridges are burned. The early success of this procedure warrants further study with more patients, longer follow-up, and higher levels of evidence-based investigation.

Level of Evidence: Review Article

Keywords: Rotator cuff tear, arthroscopic reconstruction, irreparable, shoulder, GraftJacket acellular human dermal matrix

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S1058-2746(09)00571-0